Skelta BPM 2017

Материал из archestra.info
Перейти к: навигация, поиск

Wonderware Skelta BPM 2017 Release Notes

Wonderware Skelta BPM 2017 Release Notes

Last revision: Friday, June 30, 2017

This document contains important information about the Wonderware Skelta BPM 2017 release. This release emphasizes on the capabilities of Wonderware Skelta BPM Packages, Forms, and Work Tasks App for Android.

In This Document

Installation Instructions

Upgrading to Wonderware Skelta BPM 2017

ISO Details

System Requirements

Product Compatibility

Key Features

General Enhancements

Deprecations

Issues Resolved

Other Information

Installation Instructions

You can use the Wonderware Skelta BPM 2017 installer to install the Wonderware Skelta BPM 2017 product.

Before installing Wonderware Skelta BPM 2017, the installer installs the following prerequisites:

  • Microsoft .NET Framework 4.6.2
  • Microsoft SQL Server System CLR Types for SQL Server 2014
  • Microsoft Report Viewer Redistributable 2015
  • Microsoft SQL Server System CLR Types for SQL Server 2016
  • Microsoft SQL Server 2016 Management Objects
  • Common Licensing API Framework
  • AIM Certificate Manager
  • AIM Identity Manager

All New! Server-based Licensing

Wonderware Skelta BPM 2017 utilizes a new server-based licensing subsystem that provides centralized license management. This replaces the legacy licensing system that was used in prior releases. Licenses must be activated before use.

If you are installing Wonderware Skelta BPM 2017 or upgrading an existing installation to Wonderware Skelta BPM 2017, you must first install and configure a license server node, and activate the licenses. The License Server can be typically installed on the Wonderware Skelta BPM Engine Server, but you can use a dedicated License Server.

Install Schneider Electric License Manager and Schneider Electric License Server from the Schneider Electric License Manager and Schneider Electric License Server folders respectively. These folders are available in the Schneider Electric Licensing folder in the ISO file.

Installing Wonderware Skelta BPM 2017

Run the Wonderware Skelta BPM 2017 installer, based on the operating system, to install Wonderware Skelta BPM 2017.

  • To install on a 64-bit computer, run WWSK-BPM2017-x64.exe.
  • To install on a 32-bit computer, run WWSK-BPM2017-x86.exe.

For detailed installation instructions, see Installing Wonderware Skelta BPM section in the Wonderware Skelta BPM Administrator Guide.

Installing Wonderware Skelta BPM Locales for Brazilian Portuguese

Run the Wonderware Skelta BPM Brazilian Portuguese Localization installer, based on the operating system, to install Wonderware Skelta BPM Locales for Brazilian Portuguese.

  • To install on a 64-bit computer, run WWSK-BPM2017-pt-BRLocale-x64.exe.
  • To install on a 32-bit computer, run WWSK-BPM2017-pt-BRLocale-x86.exe.

For detailed installation instructions, see Installing Wonderware Skelta BPM section in the Wonderware Skelta BPM Administrator Guide.

Installing Wonderware Skelta BPM 2017 Connector and Extension for System Platform

Run the respective installers, based on the operating system, to install Wonderware Skelta BPM 2017 Connector for System Platform and Wonderware Skelta BPM 2017 Extension for System Platform.

Extension

  • To install on a 64-bit computer, run Wonderware Skelta BPM 2017 Extension for System Platform-x64.exe.
  • To install on a 32-bit computer, run Wonderware Skelta BPM 2017 Extension for System Platform-x86.exe.

Connector

  • To install on both 64-bit and 32-bit computer, run Wonderware Skelta BPM 2017 Connector for System Platform.exe.

For detailed installation instructions, see Wonderware Skelta BPM Connectors and Extensions Guide > Installation Guide > Wonderware Skelta BPM Connector for System Platform.

Installing Wonderware Skelta BPM 2017 Connector and Extension for Information Server

Run the respective installers, based on the operating system, to install Wonderware Skelta BPM 2017 Connector for Information Server and Wonderware Skelta BPM 2017 Extension for Information Server.

Extension

  • To install on a 64-bit computer, run Wonderware Skelta BPM 2017 Extension for Information Server-x64.exe.
  • To install on a 32-bit computer, run Wonderware Skelta BPM 2017 Extension for Information Server-x86.exe.

Connector

  • To install on both 64-bit and 32-bit computer, run Wonderware Skelta BPM 2017 Connector for Information Server.exe.

For detailed installation instructions, see Wonderware Skelta BPM Connectors and Extensions Guide > Installation Guide > Wonderware Skelta BPM Connector for System Platform > Wonderware Skelta BPM Connector for Information Server.

Installing Wonderware Skelta BPM 2017 Extension for OPC UA

Run the Wonderware Skelta BPM 2017 Extension for OPC UA installer, based on the operating system, to install Wonderware Skelta BPM 2017 Extension for OPC UA.

  • To install on a 64-bit computer, run Wonderware Skelta BPM 2017 Extension for OPC UA-x64.exe.
  • To install on a 32-bit computer, run Wonderware Skelta BPM 2017 Extension for OPC UA-x86.exe.

For detailed installation instructions, see Wonderware Skelta BPM Connectors and Extensions Guide > Installation Guide > Wonderware Skelta BPM Extension for OPC UA.

Installing Wonderware Skelta BPM 2017 Connector for Microsoft SharePoint

  • Run the Wonderware Skelta BPM 2017 Connector for Microsoft SharePoint installer to install Wonderware Skelta BPM Connector for Microsoft SharePoint 2016.
    • To install, run WWSK-BPM2017-SP2016Connector-x64.exe.

    You can use this connector with Microsoft SharePoint 2016 server. Wonderware Skelta BPM Connector for Microsoft SharePoint supports only on-premises installation of Microsoft SharePoint 2016.

  • Run the Wonderware Skelta BPM 2017 Connector for Microsoft SharePoint installer to install Wonderware Skelta BPM Connector for Microsoft SharePoint 2013.
    • To install, run WWSK-BPM2017-SP2013Connector-x64.exe.

    You can use this connector with Microsoft SharePoint 2013 server. Wonderware Skelta BPM Connector for Microsoft SharePoint supports only on-premises installation of Microsoft SharePoint 2013.

For detailed installation instructions, see Wonderware Skelta BPM Connectors and Extensions Guide > Installation Guide > Wonderware Skelta BPM Connector for Microsoft SharePoint > Install.

For detailed instructions on upgrading to Wonderware Skelta BPM 2017 Connector for Microsoft SharePoint, see Wonderware Skelta BPM Connectors and Extensions Guide > Installation Guide > Wonderware Skelta BPM Connector for Microsoft SharePoint > Upgrade.

Installing Wonderware Skelta BPM 2017 Add-in for Microsoft Office Outlook

Run the Wonderware Skelta BPM Add-in for Microsoft Office Outlook installer, based on the operating system, to install Wonderware Skelta BPM Add-in for Microsoft Office Outlook.

  • To install on a 64-bit computer, run WWSK-BPM2017-OutlookAddins-x64.exe.
  • To install on a 32-bit computer, run WWSK-BPM2017-OutlookAddins-x86.exe.

Note: The Wonderware Skelta BPM Add-in for Microsoft Office Outlook is supported only for Microsoft Office 2010, 2013, and 2016. Based on the installed version of Microsoft Office, the respective Add-in components will be installed on the system.

For detailed installation instructions, see Wonderware Skelta BPM Administrator Guide > Installing Wonderware Skelta BPM > Installing Wonderware Skelta BPM Add-in for Microsoft Outlook.

Upgrading to Wonderware Skelta BPM 2017

You can upgrade to Wonderware Skelta BPM 2017 from the following versions:

  • Wonderware Skelta BPM 2014 and above versions.
  • Step upgrade from Skelta BPM.NET 2011 Service Pack 1 and above versions to Wonderware Skelta BPM 2014 or 2014 R2 and then to Wonderware Skelta BPM 2017.

Prerequisites

  • Upgrade all custom assemblies, such as custom activities, SOA assembles, custom event handler, custom resource provider, or any custom components to support Microsoft .Net Framework 4.6.2 and to refer to the latest version of Wonderware Skelta BPM assembly references.

Before you run the upgrade installer, do the following:

  1. To stop IIS, run command prompt as an administrator, and type iisreset/stop.
  2. Delete the SkeltaBPMTemp (C:\Windows\Temp\SkeltaBPMTemp) folder from the computer.
  3. Delete the cache files from C:\Windows\Microsoft.NET\Framework64\v4.0.xxxxx\Temporary ASP.NET Files\ based on the operating system. Delete all files and folders within this folder.
  4. Clear the browser cache after you upgrade.

For detailed instructions on upgrading to Wonderware Skelta BPM 2017, see Upgrading Wonderware Skelta BPM section in the Wonderware Skelta BPM Administrator Guide.

If you have registered to Push Notification for Work Tasks App, then do the following, before upgrading to Wonderware Skelta BPM 2017:

  1. Unregister from the Wonderware Skelta BPM Mobile Notification Service.
  2. Upgrade to Wonderware Skelta BPM 2017.
  3. Register to the Wonderware Skelta BPM Mobile Notification Service again, for enabling Push Notification for Work Tasks App.

For detailed instructions on unregistering from and registering to Wonderware Skelta BPM Mobile Notification Service, see Registering to Wonderware Skelta BPM Mobile Notification Service section in the Wonderware Skelta BPM Administrator Guide.

ISO Details

The following folders are created after you extract the ISO file of Wonderware Skelta BPM 2017:

Release Folder

  • Schneider Electric Licensing:
    • Installer executable for Schneider Electric License Server.
    • Installer executable for Schneider Electric License Manager.
  • Wonderware Skelta BPM 2017 – 32bit:
    • Installation executable for Wonderware Skelta BPM 2017
    • Wonderware Skelta BPM 2017 Add-in for Microsoft Office Outlook
    • Server Extensions folder - Executables for Wonderware Skelta BPM 2017 Extensions.
  • Wonderware Skelta BPM 2017 – 64bit:
    • Installation executable for Wonderware Skelta BPM 2017
    • Wonderware Skelta BPM 2017 Add-in for Microsoft Office Outlook
    • Wonderware Skelta BPM 2017 Connector for Microsoft SharePoint 2013
    • Wonderware Skelta BPM 2017 Connector for Microsoft SharePoint 2016
    • Server Extensions folder - Executables for Wonderware Skelta BPM 2017 Extensions.
  • Wonderware Skelta BPM 2017 – Connectors: Installation executables for Wonderware Skelta BPM 2017 Connectors, such as Wonderware Skelta BPM 2017 Connector for System Platform and Wonderware Skelta BPM 2017 Connector for Information Server.
  • Wonderware Skelta BPM 2017 – Demo and Example Content: Sample application and supporting documentation.
  • Wonderware Skelta BPM 2017 – Documentation

    Installer executable for Wonderware Skelta BPM 2017 Help which include:

    • Administrator Guide
    • Developer Guide
    • User Guide
    • Forms and Lists User Guide
    • Connectors and Extensions Guide
    • API Scenarios Guide
    • API Reference Guide
    • Release Notes
  • Wonderware Skelta BPM 2017 - Release Notes.htm: Release notes for the Wonderware Skelta BPM 2017 release.

System Requirements

The hardware and software requirements to install Wonderware Skelta BPM 2017 are as follows:

  • Hardware Requirements
  • Software Requirements
    • Operating System Requirements
    • Database Requirements
    • Browser Requirements
  • Other Requirements

Hardware Requirements

Component

Requirement

Processor

  • Minimum: 1 GHz (x86 processor) or 1.4 GHz (x64 processor)
  • Recommended: 2 GHz or faster, multi-core processor

Memory

  • Minimum: 4 GB RAM
  • Maximum (32-bit systems): 4 GB (Standard) or 64 GB (Enterprise)
  • Maximum (64-bit systems): 32 GB (Standard) or 2 TB (Enterprise)
  • For Microsoft SharePoint Environment, Minimum: 8 GB RAM

Hard Disk

  • Minimum: 10 GB of available hard disk space
  • Recommended: 100 GB or more of available hard disk space

Optical Drive

  • DVD-ROM drive (optional)

Display and Peripherals

  • SVGA (1366 x 768) to WXGA+ (1440x900) resolution monitor
  • Keyboard
  • Microsoft Mouse or compatible pointing device

Software Requirements

Operating System Requirements

Wonderware Skelta BPM runs on the following Windows Operating System versions. We recommend to apply all the critical updates pertaining to the version of the server.

Software Requirements Matrix

Windows

 

Windows Server

7 SP1

8

8.1

10

10 Anniversary Edition

2008 R2 SP1

2012

2012 R2*

2016

Enterprise,
Professional,
or Ultimate

Professional or Enterprise

 

Standard
or Enterprise

Standard or Data Center

 

32-bit or 64-bit

 

64-bit Only

Wonderware Skelta BPM 2017

Y

Y

Y

Y

Y

Y

Y

Y

Y

Wonderware Skelta BPM 2017 Extension for System Platform

Y

Y

Y

Y

Y

Y

Y

Y

Y

Wonderware Skelta BPM 2017 Connector for System Platform

N

N

Y

Y

Y

Y

Y

Y

Y

Wonderware Skelta BPM 2017 Extension for Information Server

Y

Y

Y

Y

Y

Y

Y

Y

Y

Wonderware Skelta BPM 2017 Connector for Information Server

N

N

Y

Y

Y

Y

Y

Y

Y

Wonderware Skelta BPM 2017 Extension for OPC UA

Y

Y

Y

Y

Y

Y

Y

Y

Y

* KB 2919355 is a prerequisite for Windows Server 2012 R2.

Database Requirements

Software Requirements Matrix

SQL Server 2008 R2

SQL Server 2012

SQL
Server 2014

SQL Server 2016

Oracle
Database
11g R2

SP1

SP2

 

SP1

SP2

SP3

 

SP1

Standard or Enterprise

Express
(SSMSE)

Standard or Enterprise

32-bit or 64-bit

64-bit only

32-bit or 64-bit

64-bit

 

Wonderware Skelta BPM 2017

Y

Y

S

Y

Y

Y

Y

Y

Y

Y

N

Wonderware Skelta BPM 2017 Extension for System Platform

Y

Y

S

Y

Y

Y

Y

Y

Y

Y

N

Wonderware Skelta BPM 2017 Connector for System Platform

Y

Y

S

Y

Y

Y

Y

Y

Y

Y

N

Wonderware Skelta BPM 2017 Extension for Information Server

Y

Y

S

Y

Y

Y

Y

Y

Y

Y

N

Wonderware Skelta BPM 2017 Connector for Information Server

Y

Y

S

Y

Y

Y

Y

Y

Y

Y

N

Wonderware Skelta BPM 2017 Extension for OPC UA

Y

Y

S

Y

Y

Y

Y

Y

Y

Y

N

Note: Wonderware Skelta BPM 2017 supports case sensitive databases.
Recommended collation for Microsoft SQL Server:
- SQL_Latin1_General_CP1_CI_AS
- SQL_Latin1_General_CP1_CS_AS

Browser Requirements

Software Requirements Matrix

Internet Explorer

 

Mozilla Firefox

Google Chrome

Apple Safari for Mac

10

11.0.10240.17394
11.0.42 (KB4018271)

Edge 38.14393.1066.0

53.0.3

58.0.3029.110

10.1

Wonderware Skelta BPM 2017

Y

Y

Y

Y

Y

L

Wonderware Skelta BPM 2017
Extension for System Platform

Y

Y

N

N

N

N

Wonderware Skelta BPM 2017
Connector for System Platform

Y

Y

N

N

N

N

Wonderware Skelta BPM 2017
Extension for Information Server

Y

Y

N

N

N

N

Wonderware Skelta BPM 2017
Connector for Information Server

Y

Y

N

N

N

N

Wonderware Skelta BPM 2017
Extension for OPC UA

Y

Y

N

N

N

N

Small Configuration Only

(Supports a maximum of five users
and 20 active workflow instances.)

S

Supported

Y

Limited Support

Only Inbox and Forms in Apple Safari for Mac

L

Not Supported

N

Other Requirements

Component

Requirement

Internet Information Services (IIS)

  • The appropriate version has to be installed and configured.

Supported Operating Systems
for Work Tasks

  • iOS
    • iOS 8.0 to iOS 10.3
  • Android
    • Lollipop
    • Marshmallow
    • Nougat
  • Windows
    • Windows 8.1 to Windows 10 Anniversary Edition

Supported Languages for Operating Systems

  • US English
  • German
  • French
  • Japanese
  • Simplified Chinese
  • Brazilian Portuguese

Product Compatibility

  • Wonderware Skelta BPM 2017 with SQL Server is compatible with the following virtualization environments:
    • VMware ESXi 5.0: Virtualization with High Availability and Disaster Recovery
    • VMware vSphere 5
  • Wonderware Skelta BPM 2017 is compatible with SQL Server AlwaysOn Availability Groups for SQL Server 2012.

Wonderware Skelta BPM 2017 is compatible and can coexist with the following connectors and extensions:

Connectors and Extensions

Compatibility

Coexistence

Can be Applied on

Wonderware Skelta BPM
Connector for Microsoft SharePoint

Y

Y

  • Windows SharePoint Services
    (WSS) 4.5
    or Microsoft SharePoint Foundation
    2013 (64-bit)
    or
    Microsoft SharePoint Foundation 2016 (64-bit)
  • Microsoft SharePoint Server
    2013 (64-bit)
    or
    Microsoft SharePoint Server 2016 (64-bit)
  • Cumulative update KB 3191911
    for Microsoft SharePoint Server
    2013 (May 2017 CU, 64-bit)
    or
    Cumulative update KB 3191880 for Microsoft SharePoint Server
    2016 (May 2017 CU, 64-bit)

     

Wonderware Skelta BPM Add-in for Microsoft Office Outlook

Y

 

Y

  • Microsoft Office Outlook 2010
    (32-bit and 64-bit)
  • Microsoft Office Outlook 2013
    (32-bit and 64-bit)
  • Microsoft Office Outlook 2016 (32-bit and 64-bit)

Wonderware Skelta BPM Extension for OPC UA

Y

 

Y

  • Wonderware Skelta BPM
    2017 (64-bit)
  • Wonderware Skelta BPM
    2017 (32-bit)

Wonderware Skelta BPM 2017 Connectors for System Platform (versions 2014, 2014 P01, 2014 R2, 2014 R2 SP1, and 2017) is compatible and can coexist with the following products:

Product

Version

Compatibility

Coexistence

Wonderware Application Server

  • 2017
  • 2014 R2 SP1 (v4.1)
  • 2014 R2 (v4.1)

Y

Y

Wonderware Historian Server

  • 2017
  • 2014 R2 SP1 (v11.6)
  • 2014 R2 (v11.6)

N/A

Y

Wonderware Information Server

  • 2014 R2 SP1 (v5.6)
  • 2014 R2 (v5.6)

Y

Y

Wonderware InTouch HMI

  • 2017
  • 2014 R2 SP1 (v11.1)
  • 2014 R2 (v11.1)

Y

Y

Wonderware InBatch Server

  • 2017
  • 2014 R2 SP1 (v.11.0)

N/A

Y

Key Features

Wonderware Skelta BPM 2017 offers a number of features and activities that help business users to create simple and process driven composite applications rapidly. Wonderware Skelta BPM 2017 has a robust and out-of-the-box connectivity to various enterprise systems and also provides an informative BAM to improve collaboration.

  • All New! Schneider Electric Licensing
  • Integration with ArchestrA Identity Manager
  • Support for secured Token Service
  • Support for sending/receiving emails through Office 365 - Exchange Online
  • Wonderware Skelta BPM Connector for Microsoft SharePoint 2016
  • Work Tasks App for Android
  • Enhancements in Wonderware Skelta BPM Forms infrastructure
  • Enhancements in Wonderware Skelta BPM Packages infrastructure

Forms

User interface and user experience are the most important aspects of business applications. Forms help you to create complex user interfaces with responsive design, adaptive layout, and cross-browser compatibility. Forms integrate with lists and workflows to enable rapid deployment of business applications.

Wonderware Skelta BPM 2017 comes with the following new features, enhancements, and changes:

Enhancements/New Features

  • Data Grid control
    • Support for sorting, filtering, and resizing columns.
    • Support for Grid View configuration.
    • The Persist culture-specific values property appears in Data Grid only for upgraded repository from versions prior to Wonderware Skelta BPM 2017. For a new repository, this property will not be displayed and the value will be No internally.
  • Action Bar at Form level, which helps designers to organize the actions in a toolbar format.
  • Image control with Label Position and Label-Control Area properties.
  • Button control with the Navigate To option for the Button Type property.
  • Attachment control with support for archiving and automatic purging of redundant attachment data.
  • Support for checking syntax of client-side scripts for Custom control.
  • Support for passing Null values as parameters for Stored Procedure Lookup.
  • Performance improvement for Forms.
  • Intellisense Enhancements for Script Editor.
  • Multiple value types support for Report Parameters in Report Viewer
  • A new API, SFU.getFormUrl, has been added under Forms API. This API can be used to navigate to a different form.
  • The third party control frameworks are upgraded to the following versions:
    • kendo.all - 2017.1.223
    • Intersoft Webgrid - 10.0.7200.31

Packages

Deploying artifacts from one environment or repository to another is critical for business uniformity and standardization. Packages help you to deploy artifacts, associated and child artifacts, configuration states, and containment states easily with package templates.

Wonderware Skelta BPM 2017 enhances the user interface of packages and provides you the following new features:

  • Support for resolving the Print Button and Navigate To Button forms.
  • Support for overwriting folders for Navigation Lists.
  • Support for installing packages on a machine, which does not have Wonderware Skelta BPM installed in it.
  • Performance enhancement in the pre-install, pre-update, and pre-uninstall pages, wherein these validations are performed by the Wonderware Skelta BPM Client service.
  • The Settings form of all artifacts is changed from Forms 2011 to Forms. This ensures that the UI experience is better and consistent across all the artifacts to be packaged.
  • Support for importing, installing, or uninstalling packages in silent mode.
    • Support for configuring WWSKBPMPackageManager using XML.
  • Support for Workflows with ArchestrA and MES activities.
  • Support for List and Report Generator activities.
  • Support for Associated WorkItem field while packaging a workflow.
  • Option to disable SDL validation for database scripts.
  • Support for validating Database Connections based on user input.
  • Categorized Pre-Install/Uninstall Logs and count of artifacts shown for better user experience
  • Enhancements in Packages Install/Uninstall
    • Progress Bar for displaying the progress of package installation and/or uninstallation.
    • Fine-tuned log messages.
  • Support for merging the package settings using the Save Template button for Workflow and Forms artifacts.
  • Optimization of Pre-Install Logs grid load on edit of an item.

Enterprise Console

The Enterprise Console menu lists the options available for a specific user based on their Security Group mapping.

  • By default, all standard BPM Lists will be sorted based on the Title column, in the ascending order.
  • The "Organize" option is now available for the following lists:
    • Form Controls
    • Lookup Lists
    • SOA Assembly
    • Reports


Work Task App

Wonderware Skelta BPM 2017 is supported on App Version 5.0.0.0. The Work Tasks App provides support for the following:

  • Windows 10
  • iOS 10.x
  • Android
    • Lollipop
    • Marshmallow
    • Nougat
  • Listing Date and Time values based on Time Zone.
  • Enhanced security for communication between Work Tasks App and Service Bus for iOS and Windows.
  • Option to set Home Page in Work Tasks App for Android.
  • Integration of QR Code Scanner with the Work Tasks App for Android.

General Enhancements

This section lists the other enhancements for Wonderware Skelta BPM 2017 release.

  • Fine-tuned a few areas in the application to avoid repeated database calls.
  • Support for User lookup search based on ObjectSID and objectGUID.
  • Web APIs can recognize the response received in the ODATA (Open Data Protocol) format.
  • Support for configuring content type (JSON, XML, or URL ENCODED) of the Post Data for Web APIs.
  • Support to start, stop, or restart the Wonderware Skelta BPM services using the Wonderware Skelta BPM Quick Launch application.
  • Double-clicking the Workflow, Forms, or Manage List items, which have child items, displays the child items. However, if these list items do not have any child items, then the selected list item is opened in the Design mode. If you double-click any other list items, then the selected list item is opened in the Edit mode.
  • Wonderware Skelta BPM 2017 default theme is modified to display UI content in Green colored theme. The UI theme will be in Green color, by default, after upgrading from earlier supported versions to Wonderware Skelta BPM 2017. To retain the existing theme, change the theme settings in Repository to Lite. For more information, see section Using Themes in Wonderware Skelta BPM Developer Guide.
  • Enhancements in the Wonderware Skelta BPM Installer to handle installation and configuration of Prerequisites.
  • Option to move lookups, Grids, and Views between folders.
  • Support for Service Bus created in China data center.
  • Support for a configurable option to stop all logger messages to SMC.
  • Support for returning both Result Sets and Out Parameter from Database Activity.
  • Option to upgrade Wonderware Skelta BPM in Silent Mode.
  • Silent Upgrade Manager returns status code.
  • Integration with the latest version of Wonderware Logger, which addresses a security vulnerability.
  • Support for the following Microsoft Office 2016 suite:
    • Microsoft Outlook 2016
    • Microsoft Word 2016
  • Option to assign work items to users based on roles in Cross Domain Environment.

Deprecations

The following features have been deprecated:

  • Support for Farm and Repository on Oracle database.
  • Remapped Image data type to VarBinary

Issues Resolved

The following are the important issues resolved in the Wonderware Skelta BPM 2017 release:

Forms

  • Memory leakage is observed when using a form with a Pop-Up control.
  • When a Lookup Item contains a field/column with the "&" character in its value, then the Lookup, which is configured in a Data Lookup control in Forms, does not populate the Extended Information.
  • Localized values for controls in Forms, such as Date, DateTime, and so on are not displayed in localized format in InTouch.
  • In the Data Grid control in Forms, if the Auto-load Grid property is set to Never, then the On Data Bound script runs more than once.
  • List with Attachments when used in workflows does not allow to copy the XML variable values from the Form XML to the List XML variable.
  • When the Move or Copy Item activity under Microsoft SharePoint Activities is executed in a workflow, and if the source list (document library, custom list, and so on) has a Person or Group type of column containing two or more users with the same display name, then the target list updates the respective Person or Group type of column with only 1 user instead of 2 or more users with the same display name as present in the source item.
  • If the Number control is configured with more than 4 decimal places and at the run time, the control is set with a value having more than 4 decimal places, the following error message appears:

    Input String was not in a correct format.

Work Tasks App

  • Date time values to be displayed based on locale settings while using the Work Tasks App.
  • Date mismatch in work items accessed via the Work Tasks App.

Continuous Improvements

  • Workitems are not assigned to users when the roles assigned to the users belong to multiple trusted domains.
  • In repositories with multiple providers, the entries for actor for second provider and user mappings are not created in the SKVirtualActor DB table during certain scenarios.
  • Error message in the WWSKLogger Console does not show the lookup name while fetching the data for the stored procedure lookup.
  • The WorkItem Detail View page crashes for a Work Activity when:
    • The page is opened using "Work Form" from the context-menu of a WorkItem picked from a queue.
    • A WorkItem is opened from the Inbox, by double-clicking the WorkItem picked from a queue.
  • With the multiple timeout setting configured in the Choice activity, if the workflow is paused and resumed several times, the multiple timeout output occurs more than once.
  • When you install the custom list using an existing table, the list table was not being displayed in the Existing Table list box in the Create List - Select Table page
  • The End Activity fails to kill any Activity which has been executed more than once and the latest activity execution is in the ‘Sleep’ status.
  • The output XML of a Database activity for a stored procedure does not contain the values for output parameters, when the stored procedure returns both Result Set and output parameters. However, the output XML contains only the values for the return Result Set.
  • When an email is sent to ToEmail, CC, and BCC recipients configured in the Email activity, the emails were delivered only to the recipients added in the ToEmail property, and not to the recipients added in the CC and BCC properties.
  • The workflow activity that is assigned to the queue and when that queued work item is selected by the user to act upon, an error message appears.
  • The following errors are displayed while testing the connectivity or while registering to the Mobile Notification Service.
    • Could not connect to http://qcbpmnotifications.azurewebsites.net/. Check Wonderware Skelta BPM logger for more details.
    • Registration to Wonderware Skelta BPM Mobile Notification Service failed. Check Wonderware Skelta BPM logger for more details.
  • The Filter option for Inbox, Lists, and BAM Reports is not working for the latest version of Google Chrome and Mozilla Firefox browsers.
  • Context Menu is not available for the Checklist activity in Microsoft Outlook 2013 and Microsoft Outlook 2016.

Packages

  • If the Install button is clicked multiple times while installing a package, then the artifacts are installed, as many times as the number of clicks. The same condition is applicable for package update and uninstall.
  • When a workflow with a database activity is installed through a package in the target environment, the workflow is not getting installed in the "Published" state.
  • While installing or updating a package, you can edit an artifact, if required. In the Package Configuration page, the selected artifact is focused and its Settings form is displayed. However, in the localized environment, the artifact selected for editing is not getting focused. By default, the first artifact in the package is getting focused.
  • When you roll back a package, then the Navigation List artifact, whose hierarchy has been modified, may not be uninstalled.
  • Emails are not getting delivered continuously in load condition.
  • While installing the Package in the Target Environment, the credentials configured in the Source Environment for Invoke Web Service activity are used, though the target credentials provided are different from the source environment credentials.

System Platform

  • While verifying and ensuring the correctness of workflow infrastructure specific to a gateway object, the following alert messages are displayed.
    • Attribute name _aaWFE_DeliveryStatus conflicts with another attribute in [object with workflows]
    • Attribute name _aaWFE_EventQueue conflicts with another attribute in [object with workflows]
  • Localized values for controls in Forms, such as Date, DateTime, and so on are not displayed in localized format in InTouch.
  • The Workflow Gateway Object is not displayed as expected. This issue occurs when the text size (Custom Scaling Level) for the Operating System is set to 125%.
  • Unable to provision System Platform connector in environments having large number of Users, Roles, and Groups.
  • Continuous spike in memory usage while executing workflows with OPC UA Tag Read Write activity.
  • Users are getting randomly logged out from InTouch.
  • When workflow(s) with OPCUA activities is being executed, a connection is established between the Wonderware Skelta BPM server and OPCUA for each of these activities. However, after an activity is completed, the corresponding connection is not closed. If the number of connections exceeds the maximum count allowed by the OPCUA server, the workflow goes into the FE (Failed with Errors) state.
  • Workflow will not get triggered when Galaxy security is configured with 'OS Group based' and Skelta Repository is configured with 'AD provider‘.

Other Information

This section contains important information about the known issues and limitations for Wonderware Skelta BPM 2017 release.

Known Issues

You might come across the following issues when you work with Wonderware Skelta BPM.

  • General
    • After upgrading to Wonderware Skelta BPM Connector for Microsoft SharePoint 2016, the Skelta Inbox web part added in BPM 2014 will not be rendered. This issue occurs due to the removal of the 'QueueDisplayOrder' and 'WorkflowDisplayOrder' properties, which have the 'SortedDictionary' data type. This data type is not supported in Microsoft SharePoint 2016. To resolve this issue, you have to delete the Inbox web part and add it again in the Microsoft SharePoint 2016 site.
    • When you generate a package, which has package template created before upgrading to Wonderware Skelta BPM 2017, the password entered for the artifacts in the target details are not encrypted. Hence, the artifacts are not installed. To resolve this issue, reenter the password in the Settings form of the respective artifact and then regenerate the package template.
    • In the Archestra IDE environment with Windows 10 operating system, the scripts are not getting modified or added in the Forms 2011 Script Editor.

Avantis  |   Industry Software Suites   |  OASyS  |   SimSci  |   SimSuite  |   Skelta  |   Wonderware