Skelta BPM 2014 R2 SP2

Материал из archestra.info
Перейти к: навигация, поиск

Wonderware Skelta BPM 2014 R2 SP2 Release Notes

Wonderware Skelta BPM 2014 R2 SP2 Release Notes

This document contains important information about the Wonderware Skelta BPM 2014 R2 SP2 release. This release emphasizes on the capabilities of Wonderware Skelta BPM Packages, Forms, ArchestrA Events, and Wonderware Skelta BPM Mobile Notification Service.

Review this document to know about the Wonderware Skelta BPM product.

Last revision: Thursday, February 18, 2016

Installation Instructions

You can use the Wonderware Skelta BPM 2014 R2 SP2 installer to install the Wonderware Skelta BPM 2014 R2 SP2 product.

Before installing Wonderware Skelta BPM 2014 R2 SP2, the installer installs the following prerequisites:

  • Microsoft .NET Framework 4.5
  • Microsoft SQL Server System CLR Types for SQL Server 2012
  • Microsoft SQL Server System CLR Types for SQL Server 2014
  • Microsoft SQL Server 2014 Management Objects
  • Microsoft Report Viewer Redistributable 2012

Installing Wonderware Skelta BPM 2014 R2 SP2

Run the Wonderware Skelta BPM 2014 R2 SP2 installer, based on the operating system, to install Wonderware Skelta BPM 2014 R2 SP2.

  • To install on a 64-bit computer, run WWSK-BPM2014R2-SP2-x64.exe
  • To install on a 32-bit computer, run WWSK-BPM2014R2-SP2-x86.exe

For detailed installation instructions, see Installing Wonderware Skelta BPM section in the Wonderware Skelta BPM Administrator Guide.

Installing Wonderware Skelta BPM Locales for Brazilian Portuguese

Run the Wonderware Skelta BPM Brazilian Portuguese Localization installer, based on the operating system, to install Wonderware Skelta BPM Locales for Brazilian Portuguese.

  • To install on a 64-bit computer, run WWSKBPM2014R2-SP2-pt-BRLocale-x64.exe
  • To install on a 32-bit computer, run WWSKBPM2014R2-SP2-pt-BRLocale-x86.exe

For detailed installation instructions, see Installing Wonderware Skelta BPM section in the Wonderware Skelta BPM Administrator Guide.

Installing Wonderware Skelta BPM 2014 R2 SP2 Connector and Extension for System Platform

Run the respective installers, based on the operating system, to install Wonderware Skelta BPM 2014 R2 SP2 Connector for System Platform and Wonderware Skelta BPM 2014 R2 SP2 Extension for System Platform.

Connector

  • To install on both 32-bit and 64-bit computer, run Wonderware Skelta BPM 2014 R2 SP2 Connector for System Platform.exe

Extension

  • To install on a 64-bit computer, run Wonderware Skelta BPM 2014 R2 SP2 Extension for System Platform-x64.exe
  • To install on a 32-bit computer, run Wonderware Skelta BPM 2014 R2 SP2 Extension for System Platform-x86.exe

For detailed installation instructions, see Wonderware Skelta BPM Connectors and Extensions Guide > Installation Guide > Wonderware Skelta BPM Connector for System Platform.

Installing Wonderware Skelta BPM 2014 R2 SP2 Connector and Extension for Information Server

Run the respective installers, based on the operating system, to install Wonderware Skelta BPM 2014 R2 SP2 Connector for Information Server and Wonderware Skelta BPM 2014 R2 SP2 Extension for Information Server.

Connector

  • To install on both 32-bit and 64-bit computer, run Wonderware Skelta BPM 2014 R2 SP2 Connector for Information Server.exe

Extension

  • To install on a 64-bit computer, run Wonderware Skelta BPM 2014 R2 SP2 Extension for Information Server-x64.exe
  • To install on a 32-bit computer, run Wonderware Skelta BPM 2014 R2 SP2 Extension for Information Server-x86.exe

For detailed installation instructions, see Wonderware Skelta BPM Connectors and Extensions Guide > Installation Guide > Wonderware Skelta BPM Connector for System Platform > Wonderware Skelta BPM Connector for Information Server.

Installing Wonderware Skelta BPM 2014 R2 SP2 Extension for OPC UA

Run the Wonderware Skelta BPM 2014 R2 SP2 Extension for OPC UA installer, based on the operating system, to install Wonderware Skelta BPM 2014 R2 SP2 Extension for OPC UA.

  • To install on a 64-bit computer, run Wonderware Skelta BPM 2014 R2 SP2 Extension for OPC UA-x64.exe
  • To install on a 32-bit computer, run Wonderware Skelta BPM 2014 R2 SP2 Extension for OPC UA-x86.exe

For detailed installation instructions, see Wonderware Skelta BPM Connectors and Extensions Guide > Installation Guide > Wonderware Skelta BPM Extension for OPC UA.

Installing Wonderware Skelta BPM 2014 R2 SP2 Connector for Microsoft SharePoint

Run the Wonderware Skelta BPM 2014 R2 SP2 Connector for Microsoft SharePoint installer to install Wonderware Skelta BPM Connector for Microsoft SharePoint.

  • To install on a 64-bit computer, run WWSK-BPM2014R2-SP2-SP2013Connector-x64.exe

You can use this connector with Microsoft SharePoint 2013 server. Wonderware Skelta BPM Connector for Microsoft SharePoint supports only on-premises installation of Microsoft SharePoint 2013.

You can upgrade from Wonderware Skelta BPM 2014 Connector for Microsoft SharePoint, Wonderware Skelta BPM 2014 R2 Connector for Microsoft SharePoint and Wonderware Skelta BPM 2014 R2 SP1 Connector for Microsoft SharePoint to Wonderware Skelta BPM 2014 R2 SP2 Connector for Microsoft SharePoint.

For detailed installation instructions, see Wonderware Skelta BPM Connectors and Extensions Guide > Installation Guide > Wonderware Skelta BPM Connector for Microsoft SharePoint > Install.

For detailed instructions on upgrading to Wonderware Skelta BPM 2014 R2 SP2 Connector for Microsoft SharePoint, see Wonderware Skelta BPM Connectors and Extensions Guide > Installation Guide > Wonderware Skelta BPM Connector for Microsoft SharePoint > Upgrade.

Installing Wonderware Skelta BPM 2014 R2 SP2 Add-in for Microsoft Office Outlook

Run the Wonderware Skelta BPM Add-in for Microsoft Office Outlook installer, based on the operating system, to install Wonderware Skelta BPM Add-in for Microsoft Office Outlook.

  • To install on a 64-bit computer, run WWSK-BPM2014R2-SP2-OutlookAddins-x64.exe
  • To install on a 32-bit computer, run WWSK-BPM2014R2-SP2-OutlookAddins-x86.exe

For detailed installation instructions, see Wonderware Skelta BPM Administrator Guide > Installing Wonderware Skelta BPM > Installing Wonderware Skelta BPM Add-in for Microsoft Outlook.

Upgrading to Wonderware Skelta BPM 2014 R2 SP2

You can upgrade to Wonderware Skelta BPM 2014 R2 SP2 from the following versions:

  • Wonderware Skelta BPM 2014
  • Wonderware Skelta BPM 2014 R2
  • Wonderware Skelta BPM 2014 R2 SP1

Before you run the upgrade installer, do the following:

Note: All .aspx pages are modified to conform to the Message bar standards. If you have customized any of the pages (aspx, ascx, or javascript files) in the BPMUITemplates folder, then back up the pages before you upgrade. After upgrading to Wonderware Skelta BPM 2014 R2 SP2, you must redo the customization.

  • Stop IIS. Run command prompt as an administrator, and type iisreset/stop.
  • Delete the SkeltaBPMTemp (C:\Windows\Temp\SkeltaBPMTemp) folder from the computer.
  • Delete the cache files from C:\Windows\Microsoft.NET\Framework64\v4.0.xxxxx\Temporary ASP.NET Files\ based on the operating system. Delete all files and folders within this folder.
  • Ensure to clear the browser cache after you upgrade, and before you use the upgraded product.

For detailed instructions on upgrading to Wonderware Skelta BPM 2014 R2 SP2, see Upgrading Wonderware Skelta BPM section in the Wonderware Skelta BPM Administrator Guide.

ISO Details

The following folders are created after you extract the ISO file of Wonderware Skelta BPM 2014 R2 SP2:

Release Folder

  • Connectors: Installation executables for the Wonderware Skelta BPM 2014 R2 SP2 Connectors, such as Wonderware Skelta BPM 2014 R2 SP2 Connector for System Platform and Wonderware Skelta BPM 2014 R2 SP2 Connector for Information Server.
  • Wonderware Skelta BPM 2014 R2 SP2 32bit: Installation executables for Wonderware Skelta BPM 2014 R2 SP2, Wonderware Skelta BPM 2014 R2 SP2 Add-in for Microsoft Office Outlook, and a Server Extensions folder. The Server Extensions folder contains the 32-bit executables for the Wonderware Skelta BPM 2014 R2 SP2 Extensions.
  • Wonderware Skelta BPM 2014 R2 SP2 64bit: Installation executables for Wonderware Skelta BPM 2014 R2 SP2, Wonderware Skelta BPM 2014 R2 SP2 Add-in for Microsoft Office Outlook, Wonderware Skelta BPM 2014 R2 SP2 Connector for Microsoft SharePoint, and a Server Extensions folder. The Server Extensions folder contains the 64-bit executables for the Wonderware Skelta BPM 2014 R2 SP2 Extensions.
  • Wonderware Skelta BPM 2014 R2 SP2 Demo and Example Content: Sample application and supporting documentation.
  • Wonderware Skelta BPM 2014 R2 SP2Documentation: Installer executable for Wonderware Skelta BPM 2014 R2 SP2 Help which include Administrator Guide, Developer Guide, User Guide, Forms and Lists User Guide, Connectors and Extensions Guide, API Scenarios Guide, and API Reference Guide.
  • Wonderware Skelta BPM 2014 R2 SP2 - Release Notes.html: Release notes for the Wonderware Skelta BPM 2014 R2 SP2 release.

System Requirements

The hardware and software requirements to install Wonderware Skelta BPM 2014 R2 SP2 are as follows:

  • Hardware Requirements
  • Software Requirements
    • Operating System Requirements
    • Database Requirements
    • Browser Requirements
  • Other Requirements

Hardware Requirements

Component

Requirement

Processor

  • Minimum: 1 GHz (x86 processor) or 1.4 GHz (x64 processor)
  • Recommended: 2 GHz or faster, multi-core processor

Memory

  • Minimum: 4 GB RAM
  • Maximum (32-bit systems): 4 GB (Standard) or 64 GB (Enterprise)
  • Maximum (64-bit systems): 32 GB (Standard) or 2 TB (Enterprise)
  • For Microsoft SharePoint Environment, Minimum: 8 GB RAM

Hard Disk

  • Minimum: 10 GB of available hard disk space
  • Recommended: 100 GB or more of available hard disk space

Optical Drive

  • DVD-ROM drive (optional)

Display and Peripherals

  • SVGA (1366 x 768) to WXGA+ (1440x900) resolution monitor
  • Keyboard
  • Microsoft Mouse or compatible pointing device

Note:

- Computers with more than 16 GB RAM will require more disk space for paging, hibernation, and dump files.

- Depending on complexity and size of your database server, 30 GB or more of available hard disk space is recommended. Your hard drive for the database must have adequate available disk space to support the performance requirements of your specific deployment.

Software Requirements

Operating System Requirements

Software Requirements Matrix

Windows

Windows Server

7 SP1

8

8.1

10

2008 R2 SP1

2012

2012 R2

Enterprise,
Professional,
or Ultimate

Professional or Enterprise

Standard
or Enterprise

Standard or Data Center

32-bit or 64-bit

64-bit Only

Wonderware Skelta BPM 2014 R2 SP2

S

N

Y

Y

Y

Y

Y

Wonderware Skelta BPM 2014 R2 SP2
Extension for System Platform

S

N

Y

Y

Y

Y

Y

Wonderware Skelta BPM 2014 R2 SP2
Connector for System Platform

Y

Y

Y

Y

Y

Y

Y

Wonderware Skelta BPM 2014 R2 SP2
Extension for Information Server

Y

N

Y

Y

Y

Y

Y

Wonderware Skelta BPM 2014 R2 SP2
Connector for Information Server

Y

Y

N

N

Y

Y

Y

Wonderware Skelta BPM 2014 R2 SP2
Extension for OPC UA

Y

N

Y

Y

Y

Y

Y

Database Requirements

Software Requirements Matrix

SQL Server 2008 R2

SQL Server 2012

SQL
Server 2014

Oracle
Database
11g R2
11.2.0.1.0

SP1

SP2

 

SP1

SP2

 

SP1

Standard or Enterprise

Express
(SSMSE)

Standard or Enterprise

32-bit or 64-bit

64-bit only

32-bit or 64-bit

Wonderware Skelta BPM 2014 R2 SP2

Y

Y

S

Y

Y

Y

Y

Y

Y

Wonderware Skelta BPM 2014 R2 SP2
Extension for System Platform

Y

Y

S

Y

Y

Y

Y

Y

N

Wonderware Skelta BPM 2014 R2 SP2
Connector for System Platform

Y

Y

S

Y

Y

Y

Y

N

N

Wonderware Skelta BPM 2014 R2 SP2
Extension for Information Server

Y

Y

S

Y

Y

Y

Y

Y

N

Wonderware Skelta BPM 2014 R2 SP2
Connector for Information Server

Y

Y

S

Y

Y

Y

Y

N

N

Wonderware Skelta BPM 2014 R2 SP2
Extension for OPC UA

Y

Y

S

Y

Y

Y

Y

Y

N

Note: Oracle Real Application Clusters (Oracle RAC) is not supported.

Browser Requirements

Software Requirements Matrix

Internet Explorer

 

Mozilla Firefox

Google Chrome

Apple Safari for Mac

10

11

Edge

43.0.4

47.0.2526.111 m

9.0.2

Wonderware Skelta BPM 2014 R2 SP2

Y

Y

N

Y

Y

L

Wonderware Skelta BPM 2014 R2 SP2
Extension for System Platform

Y

Y

N

N

N

N

Wonderware Skelta BPM 2014 R2 SP2
Connector for System Platform

Y

Y

N

N

N

N

Wonderware Skelta BPM 2014 R2 SP2
Extension for Information Server

Y

Y

N

N

N

N

Wonderware Skelta BPM 2014 R2 SP2
Connector for Information Server

Y

Y

N

N

N

N

Wonderware Skelta BPM 2014 R2 SP2
Extension for OPC UA

Y

Y

N

N

N

N

Small Configuration Only

(Supports a maximum of five users
and 20 active workflow instances.)

S

Supported

Y

Limited Support

(In Apple Safari for Mac,
only Inbox and Forms are supported.)

L

Not Supported

N

Other Requirements

Component

Requirement

Internet Information Services (IIS)

  • 7, 7.1 SP1, and 7.5
    (Windows 7, Windows Server 2008 R2,
    and Windows Server 2008 R2 SP1)
  • 8.0
    (Windows Server 2012, Windows 8.1,
    and Windows Server 2012 R2)

Supported Mobile Operating Systems

  • iOS 8.0 to iOS 9.2

Supported Operating Systems
for Windows 8.1 Work Tasks
developer build version

  • Windows 8.1

Supported Architecture
for Windows 8.1 Work Tasks
developer build version

  • ARM, x86, and x64

Supported Languages for Operating Systems

  • US English, German, French, Japanese,
    Simplified Chinese, and Brazilian Portuguese.

Product Compatibility

  • Wonderware Skelta BPM 2014 R2 SP2 with SQL Server is compatible with the following virtualization environments:
    • VMware ESXi 5.0: Virtualization with High Availability and Disaster Recovery
    • VMware vSphere 5
  • Wonderware Skelta BPM 2014 R2 SP2 is compatible with SQL Server AlwaysOn Availability Groups for SQL Server 2012.

Wonderware Skelta BPM 2014 R2 SP2 is compatible and can coexist with the following connectors and extensions:

Connectors and Extensions

Compatibility

Coexistence

Can be Applied on

Wonderware Skelta BPM 2014 R2 SP2
Connector for Microsoft SharePoint

  • Wonderware Skelta BPM
    2014 R2 SP2 (64-bit)

Y

  • Windows SharePoint Services
    (WSS) 4.5
    or Microsoft SharePoint Foundation
    2013 (64-bit)
  • Microsoft SharePoint Server
    2013 (64-bit)
  • Cumulative update KB3054866
    for Microsoft SharePoint Server
    2013 (64-bit)

     

Wonderware Skelta BPM 2014 R2 SP2
Add-in for Microsoft Office Outlook

  • Microsoft Office Outlook 2010
    (32-bit and 64-bit)
  • Microsoft Office Outlook 2013
    (32-bit and 64-bit)

     

Y

NA

Wonderware Skelta BPM Extension for OPC UA

  • Wonderware Skelta BPM
    2014 R2 SP2 (64-bit)
  • Wonderware Skelta BPM
    2014 R2 SP2 (32-bit)

     

Y

NA

Wonderware Skelta BPM 2014 R2 SP2 Connectors for System Platform (versions 2014, 2014 P01, 2014 R2, and 2014 R2 SP1) is compatible and can coexist with the following products:

Product

Version

Compatibility

Coexistence

Wonderware Application Server

  • 2014 (v4.0)
  • 2014 R2 (v4.1)
  • 2014 R2 SP1 (v4.1)

Y

Y

Wonderware Historian Server

  • 2014 (v11.5)
  • 2014 R2 (v11.6)
  • 2014 R2 SP1 (v11.6)

N/A

Y

Wonderware Information Server

  • 2014 (v5.5)
  • 2014 R2 (v5.6)
  • 2014 R2 SP1 (v5.6)

Y

Y

Wonderware Intelligence

  • 2012 (v1.5.1)

N/A

Y

Wonderware InTouch HMI

  • 2014 (v11.0)
  • 2014 R2 (v11.1)
  • 2014 R2 SP1 (v11.1)

Y

Y

Wonderware InBatch Server

  • 2014 R2 SP1 (v.11.0)

N/A

Y

Wonderware Skelta BPM 2014 R2 SP2 ArchestrA Events feature is compatible and can coexist with the following versions of Wonderware System Platform and Wonderware InBatch Server:

Component

Version

Compatibility

Coexistence

 

 

Standalone Environment

Distributed Environment

 

Wonderware System Platform

 

2014 R2 SP1

Y

Y

Y

2014 R2

Y

N

Y

2014 P01

Y

N

Y

2014

N

N

Y

Wonderware InBatch Server

 

2014 R2 SP1

Y

Y

Y

2014 R2

Y

N

Y

Key Features

Wonderware Skelta BPM 2014 R2 SP2 offers a number of features and activities that help business users create simple and process driven composite applications rapidly. Wonderware Skelta BPM 2014 R2 SP2 has a robust and out-of-the-box connectivity to various enterprise systems and also provides an informative BAM to improve collaboration.

Alternate Actor Enhancements

The following enhancements have been made to Alternate Actors:

  • Set multiple alternate actors for the same actor based on different date range.
  • Use the Audit History button to see the complete history of changes for the available alternate actors configured for a particular repository.
  • Set the Date Configuration Flag for Alternate Actors in the Wonderware Skelta BPM Central Configuration site where you can set the From date and To date as mandatory while creating alternate actors.

Forms

User interface and user experience are the most important aspects of business applications. Forms help you to create complex user interfaces with responsive design, adaptive layout, and cross-browser compatibility. Forms integrate with lists and workflows to enable rapid deployment of business applications.

Wonderware Skelta BPM 2014 R2 SP2 comes with the following features and enhancements:

The following new controls are introduced:

  • Rich Text
  • Tree
  • Gauge
  • Embed Form

The following enhancements have been made to existing controls:

  • Data Grid control with Hierarchical Grid support.
  • Pop-Up control with Persist Form Definition property.
  • Base Form control with Record Visible and Show Column Name property.
  • Panel Form control with Read-Only option for Behavior property.
  • Forms with List Structure feature.
  • The Invoke workflow control is enhanced so that you do not need to publish the workflow every time the properties are edited. However, you must publish the workflow again after you edit the following properties:
    • Workflow Details
    • XML Variable Name
    • XML Schema

The following new features are introduced in Forms:

  • You can print forms.
  • You can submit forms by pressing the Enter key.
  • Lookup configurations can now be consumed within custom controls.

The third party control frameworks are upgraded to the following versions:

  • jquery - 1.9.1
  • knockout - 3.3.0
  • knockout-kendo - 0.9.5

If you are using a custom html page that refers to jquery-1.9.1.min.js and knockout-3.1.0, then replace these references with jquery.min.js and knockout.min.js, respectively.

Packages

Deploying artifacts from one environment or repository to another is critical for business uniformity and standardization. Packages help you to deploy artifacts, associated and child artifacts, configuration states, and containment states easily with package templates.

Wonderware Skelta BPM 2014 R2 SP2 enhances the user interface of packages and provides you the following new features:

  • Package settings form conversion from Forms 2011 to utilize the rich infrastructure of Forms.

  • Packaging has been introduced for the following artifacts:
    • Forms Control Folder support
    • ASB Events
    • Forms Tree Control
    • MES XML Command Activity
    • List items of Manage List

  • SQL Script generation and execution while packaging - When a package contains a Manage List with an existing custom list, a database lookup, a queue, or a database activity, while configuring the package template in the source environment, a script is generated and populated in the newly introduced SQL script text area. While installing the package in the target environment, the SQL script is run first and then the package is installed. You can also add customized script at the start or at the end of the auto-generated SQL script. In artifacts such as Database Connection, where the SQL script is not auto-generated, a provision to add a customized SQL script is available.

  • Introduced Include Child Item option for adding child items of a folder in package template.

  • Enhanced Rebuild option for workflow to regenerate the settings form for the modified workflows in an existing package template. You can right-click the workflow from the left hand side configuration tree view in the package template, and click Complete Rebuild or Activity Rebuild to rebuild the workflow. For more information, see Wonderware Skelta BPM Developer Guide > Wonderware Skelta BPM Packages > Adding Artifacts to a Package Template > Workflows.

  • Enhanced Rebuild option for forms to build a package template when a form is modified in an existing package template. You can right-click the form from the left hand side configuration tree view in the package template, and click Complete Rebuild or Control Rebuild to rebuild the form. For more information, see Wonderware Skelta BPM Developer Guide > Wonderware Skelta BPM Packages > Adding Artifacts to a Package Template > Forms.

  • While configuring the package, you can configure the package template to add additional custom files to be installed in the target environment. Click Additional Package Files on the configuration tree view at the left hand side of the Add to Package Template window. The settings form appears where you can add the required files.

  • Introduced multi-level logging in artifacts.

  • All instances of Download and Upload in the user interface are changed to Export and Import. Starting this version, use the Export button on the action bar (or context menu option) of the Package Template window to download a package template. Similarly, use the Import button on the action bar (or context menu option) of the Manage Package window to upload a package.

Wonderware Skelta BPM Mobile Notification Service

The Wonderware Skelta BPM Mobile Notification Service handles push notifications through Azure Notification Hubs, and also ensures reliable delivery of notification to the registered mobile application.

Workflow Association with ArchestrA Events

A new activity, ArchestrA Wait for Event is introduced to wait for a number of events from ArchestrA Event Services platform for a particular time period, and then consume the events in a defined workflow. You can set the number of events and the time period in the properties of that activity. It can store the event context details in the specified XML variable.

Work Task App

Wonderware Skelta BPM 2014 R2 SP2 is supported on App Version 4.3.0.0. This release supports iOS 8.0 to iOS 9.2 and Windows 8.1 for Work Tasks App.

New Features

The following new features have been introduced in Wonderware Skelta BPM 2014 R2 SP2:

  • IPv6 Addressing
  • Auto Log Off
  • Message Bar

IPv6 Addressing

Wonderware Skelta BPM 2014 R2 SP2 allows you IPv6 addressing for communication between servers and database.

Auto Log off

To enhance security, Wonderware Skelta BPM 2014 R2 SP2 now comes with the Auto Log Off feature. Configure the auto log off time interval to automatically log out the currently logged in user, after a designated period of inactivity.

Message Bar

In Wonderware Skelta BPM 2014 R2 SP2, user prompts for alerts and messages has been upgraded to Message bar.

Enable/Disable Pop-Up Messages in Inbox

Use the Display pop-up messages while acting on a Queue item in Inbox option in the Property Grid of Web Parts to enable or disable pop-up messages in the inbox, while performing actions on queue work items in inbox.

Issues Resolved

The following are the important issues resolved in the Wonderware Skelta BPM 2014 R2 SP2 release:

  • Under maximum concurrent load conditions, the Database Activity outputs that are saved to an XML variable gets swapped between instances.
  • While saving a layout in Inbox, the layout is saved but the customization done for the particular layout is not retained.
  • When you try to filter a large number of records for a List view, the page times out.
  • After you create a view with any filter condition and apply that view to a list, and then if you try to filter the list information again using the Filter Bar in the web grid menu, the list page crashes.
  • Show Queue Detailed View Without Picking option is not working for Forms.
  • Users who are part of a group that has the queue view rights are unable to view queues in Inbox of Enterprise Console
  • Escalation in a Queue creates multiple Work Items in the Queue even after the work item has been picked
  • Activity output is not setting to Error Encountered when an internal error occurs. A workflow, containing a child workflow, completes execution even if the child workflow is waiting for an activity to complete. The parent workflow successfully completes execution without any error notification even when the child workflow has pending activities and the Exit Activity with Error Output of the child workflow is set to Error Encountered.
  • Unable to edit URL and Email link from the Workflow Memo property in the Process Designer. For example, when you right-click on the link entered, the context sensitive menu does not appear.
  • When a list is auto generated to a form, and is redesigned, the form appears blank and the following error message appears:

    500 Internal Server Error

  • WorkitemInboxCount control does not display the correct count of work items in Inbox if ViewEngine is deployed in terminal services. The WorkitemInboxCount control shows the count of work items as 0, and the InTouch application takes longer time to respond when the terminal server is accessed remotely.
  • For a workflow with Invoke Form Activity, when you click the Submitted Form Details in BAM, the latest version of the form is displayed, irrespective of the version of the form configured in Invoke Form Activity.
  • Unable to copy paste activities from different process designer instances in Internet Explorer.

Other Information

You might come across the following limitations when you work with Wonderware Skelta BPM.

General

  • When you upgrade Wonderware Skelta BPM using the Upgrade Manager tool through installer, the upgrade might not be successful due to rights issue. Run the Upgrade Manager tool manually with the Run as Administrator option. You can find the Upgrade Manager tool, SkeltaUpgradeManager.exe, in the BIN folder of the Wonderware Skelta BPM install path.

ArchestrA IDE and InTouch Node

  • In a distributed environment, Internet Explorer 10 or Internet Explorer 11 must be installed in all the ArchestrA IDE nodes. Also, the registry files for the respective Internet Explorer version must be merged. The following registry files are shipped with Wonderware Skelta BPM Connector for System Platform:
    • WebBrowserControlIEVersion_10_x86.reg and WebBrowserControlIEVersion_10_x64.reg for Internet Explorer 10.
    • WebBrowserControlIEVersion_11_x86.reg and WebBrowserControlIEVersion_11_x64.reg for Internet Explorer 11.
  • In a distributed environment, about:security_aaIDE.exe and about:security_view.exe must be added to the Trusted Sites list of Internet Explorer to resolve the Forms behavior issue for ArchestrA IDE environment and InTouch Node in the Windows Operating Systems.

Forms

  • While localizing text containing $ character, the text is not localized as expected.
  • If you use Rich Text (Kendo) as a custom control, then see the related KB article TN1185 if you have upgraded to Wonderware Skelta BPM 2014 R2 SP2.
  • In Forms 2011, the user interface messages and error messages do not conform to the Message bar standards.
  • You cannot view a form, from the Submitted Form Details tab of BAM reports, for a workflow containing Invoke Form Activity, configured with Forms 2011.

Packages

  • Auto-generation of SQL script while configuring a package template is not supported for an Oracle database.
  • If you are using Mozilla Firefox, and in the package tree view, if you click the context menu, then the Message bar is not displayed. Instead, a JavaScript notification is displayed.

top of document